Step-by-Step Guide: Rapid Oral Confirmation (Non-Negative)

1. Validate the Non-Negative Result

  • If the rapid oral test comes back non-negative, select Validate Test.
  • Wait the required 3 minutes for validation.

2. Confirm Non-Negative Result

  • After 3 minutes, review the result again.
  • If the test is still non-negative, click “Sign & Send.”
    • Do NOT click “Send to Lab” for the rapid oral result.

3. Begin Confirmation Collection (Omega Paper Chain + Quantisal Kit)

  • Immediately collect a confirmation oral fluid sample using:
    • Omega paper chain of custody
    • Quantisal oral fluid kit

4. Collect the Oral Fluid Sample

  • Hand the donor the Quantisal swab.
  • Instruct them to:
    • Place the cotton pad in their mouth for 5 minutes
    • Do not bite or chew the swab
  • While the donor is collecting, begin completing the Omega paper chain.

5. Seal the Quantisal Specimen

  • After 5 minutes, put on gloves.
  • Take the swab from the donor and place it into the testing tube.
  • Seal the tube using the provided sticker/seal.
  • Have the donor initial the seal.
  • You will date the seal.

6. Enter the Confirmation Test in Labb

  • On your tablet, locate the correct organization.
  • Select “Universal Chain.”
  • Select the appropriate confirmation panel for the oral fluid test.
  • Follow the prompts on the tablet to complete the collection entry.

7. Confirm Collection Upload

  • After submission, go to the Labb Dashboard.
  • You should see the donor listed with a status such as:
    • Collection Complete
  • This is where the confirmation results will upload once processed.

8. Educate and Release the Donor

  • Let the donor know:
    • The specimen has been sent for confirmation testing.
    • An MRO may call from an unknown number.
    • They should answer the call to verify any prescriptions or medications.
  • Return the donor’s ID.
  • Let the donor know they are good to leave.

9. Add Notes to Rapid Result

  • In the original rapid oral test result entry, add a note stating:
    • Results are not finalized — specimen sent for confirmation.
Table of Contents